Highly Purified Media
Multi Column Distillation (WFI) Plant
INJECTABLE ITEMS
The Multi Column Distillation Plant is available in various configurations with a wide range of instrumentation for untouched fully automated operation. It is designed and fabricated as per fabrication code ASME SEC Viii DIV & TEMA.
Application:
To produce IP/BP/USP compliance WFI for the manufacturing process and clean in place of process vessels & pipings.
Optional Accessories :
• SCADA with IPC
- Saving raw steam consumption by maximum utilization of heat through Multi Effect Evaporation.
- Capacity available 50 to 5000 liters/hr.
- Double Tube Sheet construction for Feed water, cooling water & condenser column.
- Electro-polished SS 316L tubes to provide a smoother surface to reduce microbiological growth & erosion-corrosion.
- Auto dumping of substandard WFI through temperature & conducting base and Flow monitoring through Flow Meter (optional).
- The auto drainage system of the first & last column with level switch.
- Online monitoring of feed water & cooling water through the flow meter.
- WFI quality through conducting sensor.
- Sampling facility for laboratory tests.
- Cartridge Type Filter Housing for Feed Water (optional).
- Complete steam station for raw steam with PID pneumatic valve (optional).
- Fully automated PLC-based system with four levels of security.
- 21CFR Part 11 compliance.
- All pipe joints are orbitally welded.
SYSTEM REQUIREMENT
Feed Water:
• Purified water as per USP32 with max conductivity of 1 micro-ohm.
• Pressure should be 1kg/cm2 higher than the raw steam pressure.
• Temperature Ambient 30OC
Feed Steam:
• Steam must be saturated, dry free from oil, vapors & other impurities. (A steam filter to obtain 3µ, clear quality steam)
• Steam pressure min 6kg/cm2 is essential to guarantee pyrogen-free distillate.